def _reconfigure_port(self, force_update=True):
"""Set communication parameters on opened port."""
super(VTIMESerial, self)._reconfigure_port()
fcntl.fcntl(self.fd, fcntl.F_SETFL, 0) # clear O_NONBLOCK
if self._inter_byte_timeout is not None:
vmin = 1
vtime = int(self._inter_byte_timeout * 10)
else:
vmin = 0
vtime = int(self._timeout * 10)
try:
orig_attr = termios.tcgetattr(self.fd)
iflag, oflag, cflag, lflag, ispeed, ospeed, cc = orig_attr
except termios.error as msg: # if a port is nonexistent but has a /dev file, it'll fail here
raise serial.SerialException("Could not configure port: %s" % msg)
if vtime < 0 or vtime > 255:
raise ValueError('Invalid vtime: %r' % vtime)
cc[termios.VTIME] = vtime
cc[termios.VMIN] = vmin
termios.tcsetattr(
self.fd,
termios.TCSANOW,
[iflag, oflag, cflag, lflag, ispeed, ospeed, cc])